Key Features
- Fan speed adjustment is possible
- Alarm function can be used to check when Ion Balance / Fan operation is abnormal.
- Ion Balance ± Within 30V (300mm)
- Real-time automatic Ion Balance maintained
- Ion Balance can be adjusted manually
- Fan filter attachable and removable for easy replacement
- Automatic discharge needle cleaning function for convenient maintenance
- Compatible with automation facilities (PLC, RS-485)
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
| Parameter | Description / Value | |
|---|---|---|
| Input Power | DC 24V (Adaptor [AC110~220V, 50/60Hz, DC 24V,2.5A]) | |
| Power Consumption | 35W | |
| Current Consumption | 159mA (AC 220V) | |
| Ion-Generation Method | Steady-State DC | |
| Air Flow | 4.84m³/min | |
| Noise Level | 62dB | |
| Ion Balance | within ±5V (600mm, Maximum Air flow) | |
| Ozone(O3) Concentration | ≤0.05ppm | |
| Operation Circumstance | 0˚C~+50˚C(32˚F~122˚F), 35%~85%RH | |
| Main Body Material | EGI | |
| Electrode Material | Standard | Tungsten |
| Option | Titanium | |
| Mounting Method | Desktop | |
| Weight | 1.94kg | |
| Function | Tip Cleaning, 2 Steps Fan Speed, Ion Balance Display | |
| Alarm Function | Ion Unbalance Alarm | |
| Interface | Remote On/Off, Run State, RS485, Alarm(Ion Unbalance), Tip Cleaning | |
| Warranty | 1 year | |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
Dimensions