SXB-10W Series
Key Features
- Waterproof (IPX7) ° dustproof (IP5X) construction for use in humid spaces
- Ion Balance ± 0V
- Maintain initial performance over its lifetime
- No Clean Dry Air (CDA) required, no particle scattering
- Apply up to 9 tubes for a wide range of festivals
- Tube module structure for quick on-site replacement with easy separation and mating
- Economical maintenance by purchasing the tube separately
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
| Parameter | Description / Value |
|---|---|
| Ion Generation Method | Soft X-ray |
| Source | Soft X-ray Tube |
| Tube Voltage | 11kV |
| Beam Angle | 150˚ |
| Power Consumption | Max. 130W |
| Waterproof Grade | IPX7 |
| Dustproof Grade | IP5X |
| Operation Circumstance | 0℃ ~ +50℃(32℉ ~ 122℉) |
| Warranty | 1 year |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
Dimensions
Dimensions Table
| No. | Model No. | Tube Q’ty | A | B | C | D | Mid. BRKT Q’ty |
|---|---|---|---|---|---|---|---|
| 1 | SXB-10W-300-1 | 1 | 324 | 374 | 374 | – | – |
| 2 | SXB-10W-600-2 | 2 | 635 | 685 | 685 | 311 | 2 |
| 3 | SXB-10W-900-3 | 3 | 946 | 996 | 996 | ||
| 4 | SXB-10W-1200-4 | 4 | 1257 | 1307 | 1307 | ||
| 5 | SXB-10W-1500-5 | 5 | 1568 | 1618 | 1618 | ||
| 6 | SXB-10W-1800-6 | 6 | 1879 | 1929 | 1929 | ||
| 7 | SXB-10W-2200-7 | 7 | 2190 | 2240 | 2240 | 3 | |
| 8 | SXB-10W-2500-8 | 8 | 2501 | 2551 | 2551 | ||
| 9 | SXB-10W-2800-9 | 9 | 2812 | 2862 | 2862 | ||
| 10 | SXB-10W-3100-10 | 10 | 3123 | 3173 | 3173 | ||
| 11 | SXB-10W-3400-11 | 11 | 3434 | 3484 | 3484 |
Shielding method
- Please refer to the following graph and table to select the material and thickness of the shield.
- Warring
- For the safety of the user, please be sure to shield the irradiation space where the X-ray is generated.
- After shielding, connect the interlock contacts to the door so that when the door is opened, the X-ray generation stops.
Shielding installation diagram
- If soft X-rays are directly irradiated to the human body, they may affect the skin, so be sure to use shielding as shown in the figure.
- Before running the Soft X-Ray Ionizer, check the shielding status of the equipment and use the interlock function.
- The radiation dose should be kept below 1μSv/hr for 5kV products and 10μSv/hr for 10kV & 15kV products. (Leakage standards may vary by country)
Option
Key Features
- Repeater to extend the length of the cable connecting the Photo Bar and the Controller
- Cable lengths can be extended up to 10 m
Download
You will receive catalogues, manuals and leaflets.
Specifications
| Parameter | Description / Value |
|---|---|
| Weight | 0.26kg |
| Warranty | 1 year |