Home / Business Area / Electrostatic Solution / Soft X-ray Ionizer / SXH-05SI
SXH-05SI
Key Features
- By ionizing gases (N₂, CDA), it is possible to discharge electricity inside the piping
- Tube module structure for quick on-site replacement with easy separation and mating
- Economical maintenance by purchasing the tube separately
- Ion Balance ± 0V
- Maintain initial performance throughout its lifetime
- No CDA required, no particle scattering
- According to Article 8 of the Enforcement Decree of the Nuclear Safety Act, it may be excluded from regulation according to tube voltage.
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
Parameter | Description / Value |
---|---|
Ion Generation Method | Soft X-ray |
Source | Soft X-ray Tube |
Tube Voltage | 4.9kV |
Beam Angle | 150˚ |
Air Purge Supply Pressure | 0.1~0.4MPa (CDA [Clean Dry Air],N2) |
Power Consumption | Max. 10W (Head 1개 기준) |
Operation Circumstance | 0℃ ~ +50℃(32℉ ~ 122℉), 35% ~ 85% RH |
Weight | 0.52kg |
Warranty | 1 year |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
Dimensions
Shielding method
- Please refer to the following graph and table to select the material and thickness of the shield.
- Warring
- For the safety of the user, please be sure to shield the irradiation space where the X-ray is generated.
- After shielding, connect the interlock contacts to the door so that when the door is opened, the X-ray generation stops.
Shielding installation diagram
- If soft X-rays are directly irradiated to the human body, they may affect the skin, so be sure to use shielding as shown in the figure.
- Before running the Soft X-Ray Ionizer, check the shielding status of the equipment and use the interlock function.
- The radiation dose should be kept below 1μSv/hr for 5kV products and 10μSv/hr for 10kV & 15kV products. (Leakage standards may vary by country)