※ The appearance and specification of the product may be changed without prior notice for the improvement of the product.
SXB-05NR
This is bar type ionizer having 1 to 9 X-ray windows so that is effective for ionizing wide area.
Slim size is useful to be installed in various conditions and module structure
(Rotate type replaceable tube) makes it easy to replace.
Slim size is useful to be installed in various conditions and module structure
(Rotate type replaceable tube) makes it easy to replace.
Key Features
- The smallist size in the same line of products
(possible to ionize on the surface and rear side) - No CDA needed, No scattering particle problem
- ±0V Ion Balance
- Managing process under 100V constant voltage
- Easy attachable/detachable Module structure
- Purchasing by the individual parts brings economic savings
Do you need any other help?
Do you need product inquiries or technical support? If you have any questions or concerns, please contact us here.
Parameter | Description / Value |
---|---|
Ion Generation Method | Soft X-ray |
Source | Soft X-ray Tube |
Tube Voltage | 4.9kV |
Beam Angle | 150° |
Power Consumption (with Controller) | Max. 130W |
Operation Circumstance | 0°C ~ +50°C(32°F ~ 122°F), 35% ~ 85% RH |
Weight | 1.05kg (Controller ) |
Controller | SXC-10BT / SXC-10BL |
Warranty | 1 year |
Test Conditions
- Decay Time : ±1,000V to ±100V
- Charge Plate Capacitance : 20pF(150 X 150 mm)
- Temperature & Humidity : 24℃, 50%RH
SXB-05NR-900-3
SXB-10NR-900-3
MODEL / DIMENSIONS
NO. | MODEL NO. | A | B | C | D | TUBE Q’TY |
---|---|---|---|---|---|---|
1 | SXB-05NR-300-1 | 314 | 335 | 391 | - | 1 |
2 | SXB-05NR-600-2 | 625 | 646 | 675 | 311 | 2 |
3 | SXB-05NR-900-3 | 936 | 957 | 986 | 3 | |
4 | SXB-05NR-1200-4 | 1247 | 1268 | 1297 | 4 | |
5 | SXB-05NR-1500-4 | 1558 | 1579 | 1608 | 414.6 | 4 |
6 | SXB-05NR-1500-5 | 1558 | 1579 | 1608 | 311 | 5 |
7 | SXB-05NR-1800-5 | 1869 | 1890 | 1919 | 388.8 | 5 |
8 | SXB-05NR-1800-6 | 1869 | 1890 | 1919 | 311 | 6 |
9 | SXB-05NR-2200-6 | 2180 | 2201 | 2230 | 373.2 | 6 |
10 | SXB-05NR-2200-7 | 2180 | 2201 | 2230 | 311 | 7 |
11 | SXB-05NR-2500-7 | 2491 | 2512 | 2541 | 362.8 | 7 |
12 | SXB-05NR-2500-8 | 2491 | 2512 | 2541 | 311 | 8 |
13 | SXB-05NR-2800-7 | 2802 | 2823 | 2852 | 414.6 | 7 |
14 | SXB-05NR-2800-9 | 2802 | 2823 | 2852 | 311 | 9 |
No. | Model | A | B | C | D | TUBE Q’TY |
---|---|---|---|---|---|---|
1 | SXB-10NR-300-1 | 314 | 335 | 364 | - | 1 |
2 | SXB-10NR-600-2 | 625 | 646 | 675 | 311 | 2 |
3 | SXB-10NR-900-3 | 936 | 957 | 986 | 3 | |
4 | SXB-10NR-1200-4 | 1247 | 1268 | 1297 | 4 | |
5 | SXB-10NR-1500-4 | 1558 | 1579 | 1608 | 414.6 | 4 |
6 | SXB-10NR-1500-5 | 1558 | 1579 | 1608 | 311 | 5 |
7 | SXB-10NR-1800-5 | 1869 | 1890 | 1919 | 388.8 | 5 |
8 | SXB-10NR-1800-6 | 1869 | 1890 | 1919 | 311 | 6 |
9 | SXB-10NR-2200-6 | 2180 | 2201 | 2230 | 373.2 | 6 |
10 | SXB-10NR-2200-7 | 2180 | 2201 | 2230 | 311 | 7 |
11 | SXB-10NR-2500-7 | 2491 | 2512 | 2541 | 362.8 | 7 |
12 | SXB-10NR-2500-8 | 2491 | 2512 | 2541 | 311 | 8 |
13 | SXB-10NR-2800-7 | 2802 | 2823 | 2852 | 414.6 | 7 |
14 | SXB-10NR-2800-9 | 2802 | 2823 | 2852 | 311 | 9 |
15 | SXB-10NR-900-2 | 936 | 957 | 986 | 622 | 2 |
16 | SXB-10NR-1200-3 | 1247 | 1268 | 1297 | 466.5 | 3 |
17 | SXB-10NR-1500-3 | 1558 | 1579 | 1612 | 622 | 3 |
18 | SXB-10NR-1800-4 | 1869 | 1890 | 1919 | 518.3 | 4 |
19 | SXB-10NR-2200-4 | 2180 | 2201 | 2230 | 622 | 4 |
20 | SXB-10NR-2800-5 | 2802 | 2823 | 2852 | 5 | |
21 | SXB-10NR-3400-6 | 3424 | 3445 | 3474 | 6 |
Download Catalogue, Manual & Leaflet
Please click here to download various contents such as product catalog, product manual, product leaflet etc.
Technical Support
Do you need product inquiries or technical support? If you have any questions or concerns, please contact us here.
Telephone Consultation
If you can not find the information you want on our website, please call us at Please contact us or any inquiries.
- Features
-
SXB-05NR
This is bar type ionizer having 1 to 9 X-ray windows so that is effective for ionizing wide area.
Slim size is useful to be installed in various conditions and module structure
(Rotate type replaceable tube) makes it easy to replace.Key Features
- The smallist size in the same line of products
(possible to ionize on the surface and rear side) - No CDA needed, No scattering particle problem
- ±0V Ion Balance
- Managing process under 100V constant voltage
- Easy attachable/detachable Module structure
- Purchasing by the individual parts brings economic savings
Do you need any other help?
Do you need product inquiries or technical support? If you have any questions or concerns, please contact us here. - The smallist size in the same line of products
- Specification
-
Parameter Description / Value Ion Generation Method Soft X-ray Source Soft X-ray Tube Tube Voltage 4.9kV Beam Angle 150° Power Consumption (with Controller) Max. 130W Operation Circumstance 0°C ~ +50°C(32°F ~ 122°F), 35% ~ 85% RH Weight 1.05kg (Controller ) Controller SXC-10BT / SXC-10BL Warranty 1 year ※ The appearance and specification of the product may be changed without prior notice for the improvement of the product.
- Decay Time Characteristics
-
Test Conditions
- Decay Time : ±1,000V to ±100V
- Charge Plate Capacitance : 20pF(150 X 150 mm)
- Temperature & Humidity : 24℃, 50%RH
SXB-05NR-900-3
SXB-10NR-900-3
- Dimensions
-
MODEL / DIMENSIONS
NO. MODEL NO. A B C D TUBE Q’TY 1 SXB-05NR-300-1 314 335 391 - 1 2 SXB-05NR-600-2 625 646 675 311 2 3 SXB-05NR-900-3 936 957 986 3 4 SXB-05NR-1200-4 1247 1268 1297 4 5 SXB-05NR-1500-4 1558 1579 1608 414.6 4 6 SXB-05NR-1500-5 1558 1579 1608 311 5 7 SXB-05NR-1800-5 1869 1890 1919 388.8 5 8 SXB-05NR-1800-6 1869 1890 1919 311 6 9 SXB-05NR-2200-6 2180 2201 2230 373.2 6 10 SXB-05NR-2200-7 2180 2201 2230 311 7 11 SXB-05NR-2500-7 2491 2512 2541 362.8 7 12 SXB-05NR-2500-8 2491 2512 2541 311 8 13 SXB-05NR-2800-7 2802 2823 2852 414.6 7 14 SXB-05NR-2800-9 2802 2823 2852 311 9 No. Model A B C D TUBE Q’TY 1 SXB-10NR-300-1 314 335 364 - 1 2 SXB-10NR-600-2 625 646 675 311 2 3 SXB-10NR-900-3 936 957 986 3 4 SXB-10NR-1200-4 1247 1268 1297 4 5 SXB-10NR-1500-4 1558 1579 1608 414.6 4 6 SXB-10NR-1500-5 1558 1579 1608 311 5 7 SXB-10NR-1800-5 1869 1890 1919 388.8 5 8 SXB-10NR-1800-6 1869 1890 1919 311 6 9 SXB-10NR-2200-6 2180 2201 2230 373.2 6 10 SXB-10NR-2200-7 2180 2201 2230 311 7 11 SXB-10NR-2500-7 2491 2512 2541 362.8 7 12 SXB-10NR-2500-8 2491 2512 2541 311 8 13 SXB-10NR-2800-7 2802 2823 2852 414.6 7 14 SXB-10NR-2800-9 2802 2823 2852 311 9 15 SXB-10NR-900-2 936 957 986 622 2 16 SXB-10NR-1200-3 1247 1268 1297 466.5 3 17 SXB-10NR-1500-3 1558 1579 1612 622 3 18 SXB-10NR-1800-4 1869 1890 1919 518.3 4 19 SXB-10NR-2200-4 2180 2201 2230 622 4 20 SXB-10NR-2800-5 2802 2823 2852 5 21 SXB-10NR-3400-6 3424 3445 3474 6 - Shielding Methods
-
- Download
-
Download Catalogue, Manual & Leaflet
Please click here to download various contents such as product catalog, product manual, product leaflet etc.Technical Support
Do you need product inquiries or technical support? If you have any questions or concerns, please contact us here.Telephone Consultation
If you can not find the information you want on our website, please call us at Please contact us or any inquiries.