Home / Business Area / Electrostatic Solution / Soft X-ray Ionizer / SXH-05SP1
SXH-05SP1
Key Features
- By applying PIN Type Tube, it is possible to install and discharge power in a small space such as the lower part of the stage.
- Ion Balance ± 0V
- Maintain initial performance over its lifetime
- No Clean Dry Air (CDA) required, no particle scattering
- According to Article 8 of the Enforcement Decree of the Nuclear Safety Act, it may be excluded from regulation according to tube voltage. (SXH-05SP1 only)
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
Parameter | Description / Value | |
---|---|---|
Ion Generation Method | Soft X-ray | |
Source | Soft X-ray Tube | |
Tube Voltage | SXH-05SP1 | 4.9kV |
SXH-10SP1 | 11kV | |
Beam Angle | 150˚ | |
Power Consumption | Max. 10W (Head 1개 기준) | |
Operation Circumstance | 0℃ ~ +50℃(32℉ ~ 122℉), 35% ~ 85% RH | |
Weight | SXH-05SP1 | 0.37kg (기본형) |
SXH-05SP1-OP | 0.46kg (튜브 교체형 _Option) | |
Warranty | 1 year |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
Dimensions - Standard
Dimensions - Option
Shielding method
- Please refer to the following graph and table to select the material and thickness of the shield.
- Warring
- For the safety of the user, please be sure to shield the irradiation space where the X-ray is generated.
- After shielding, connect the interlock contacts to the door so that when the door is opened, the X-ray generation stops.
Shielding installation diagram
- If soft X-rays are directly irradiated to the human body, they may affect the skin, so be sure to use shielding as shown in the figure.
- Before running the Soft X-Ray Ionizer, check the shielding status of the equipment and use the interlock function.
- The radiation dose should be kept below 1μSv/hr for 5kV products and 10μSv/hr for 10kV & 15kV products. (Leakage standards may vary by country)