SIB4 Series
Corona discharge loss is minimized through various specification and digital control system and this product provides high performance, low ion balance. Also, wide range of ionization is possible through optimum ion generating design.
Key Features
- Depending on the polarity, ion generation amount is automatically controlled. – Auto. Duty
- With its slim body, diverse installation is possible
- Maximized the ion creation via reducing loss of corona discharging
- Tip Cleaning Alarm (internal timer installed → possible to set tip cleaning period)
- Output voltage control (8~12.5kVp-p)
- Power jumping function among ion bars (Max. 4 ion bar links)
- Aerodynamic design nozzle socket reduces tip contamination
- One-touch in/out socket application
- Tip cleaning device (Option)
- Design for minimum air consumption (Newly designed socket minimized the air consumption but maximized the air pressure)
Specifications
Parameter | Description / Value | Remark | |
---|---|---|---|
Input Power | DC 24V (±5%) | ||
Power Consumption | Max. 14.4W | ||
Current Consumption | Max. 500mA | DC 24V | |
Ion-Generation Method | Corona Discharge Pulse AC | ||
Air Purge Supply Pressure | 0.1MPa ~ 0.5 MPa | CDA (Clean Dry Air), N2 | |
Air Purge Connection Port | Pipe Thread 1/8” | ||
Ion Balance | within ±30V | 1,000mm | |
Ozone (O3) Concentration | ≤0.05ppm | ||
Main Body Material | Non-Flammable ABS | Level V0 | |
Electrode Material | Standard : Tungsten | ||
Option : Silicon, Titanium | |||
Electrode Replacement | Cartridge type | ||
Operation Circumstance | 0°C ~ +50°C (32°F ~ 122°F), 35% ~ 85% RH | ||
Ion Bar Length | 877mm ~ 3,478mm | ||
Mounting Method | Bolt Mounting with Bracket | ||
Function | Remote Control | ||
Adjust Function | Frequency [Hz] | 0.1, 0.3, 1, 3, 5, 8, 10, 20, 30, 35, 40, 45, 50 | |
Voltage [Level] | Positive 1 ~ 10 / Negative 1 ~ 10 | ||
Duty Ratio [%] | 40 ~ 70 | ||
Auto Duty | Mode Set | Distance 50 ~ 100mm | |
Alarm Function | High Voltage Abnormal Alarm, Tip Cleaning Alarm (Setting) | ||
Interface | Run State, Remote, RS485, Alarm(High Voltage Abnormal, Tip Cleaning) | ||
Operating Distance | 50mm ~ 2,000mm | ||
Option | RMS (Real Monitoring System), SBP-RD (DC Power Supply) | ||
Warranty | 1 year |
The appearance and specification of the product may be changed without prior notice for the improvement of the product.
Decay Time Characteristics
Test Conditions
- Model : SIB4-1000
- Socket : SIE-4
- Output Voltage : Pulse AC ±10.5kVp-p
- Air Pressure : 0.3MPa
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃ ± 1℃, 40% ± 2%RH
- Charge Plate Capacitance : 20pF ± 2pF (150 X 150mm)
- Frequency : 30Hz
Dimensions
MODEL / DIMENSIONS
No. | Model No. | Tip Q’TY | A | B | C | D | E | Middle BKT Q’TY |
---|---|---|---|---|---|---|---|---|
1 | SIB4-800 | 12 | 660 | 800 | 851 | 877 | 70 | - |
2 | SIB4-900 | 14 | 780 | 881 | 932 | 958 | 50.5 | - |
3 | SIB4-1000 | 16 | 900 | 1001 | 1052 | 1078 | 50.5 | 1 |
4 | SIB4-1100 | 18 | 1020 | 1121 | 1172 | 1198 | 50.5 | 1 |
5 | SIB4-1200 | 20 | 1140 | 1241 | 1292 | 1318 | 50.5 | 1 |
6 | SIB4-1300 | 22 | 1260 | 1361 | 1412 | 1438 | 50.5 | 1 |
7 | SIB4-1500 | 24 | 1380 | 1481 | 1532 | 1558 | 50.5 | 1 |
8 | SIB4-1600 | 26 | 1500 | 1601 | 1652 | 1678 | 50.5 | 1 |
9 | SIB4-1700 | 28 | 1620 | 1721 | 1772 | 1798 | 50.5 | 2 |
10 | SIB4-1800 | 30 | 1740 | 1841 | 1892 | 1918 | 50.5 | 2 |
11 | SIB4-2000 | 32 | 1860 | 1961 | 2012 | 2038 | 50.5 | 2 |
12 | SIB4-2100 | 34 | 1980 | 2081 | 2132 | 2158 | 50.5 | 2 |
13 | SIB4-2200 | 36 | 2100 | 2201 | 2252 | 2278 | 50.5 | 2 |
14 | SIB4-2300 | 38 | 2220 | 2321 | 2372 | 2398 | 50.5 | 2 |
15 | SIB4-2500 | 40 | 2340 | 2441 | 2492 | 2518 | 50.5 | 3 |
16 | SIB4-2700 | 44 | 2580 | 2681 | 2732 | 2758 | 50.5 | 3 |
17 | SIB4-3000 | 48 | 2820 | 2921 | 2972 | 2998 | 50.5 | 3 |
18 | SIB4-3200 | 52 | 3060 | 3161 | 3212 | 3238 | 50.5 | 3 |
19 | SIB4-3400 | 56 | 3300 | 3401 | 3452 | 3478 | 50.5 | 3 |