SIB4 Series
Corona discharge loss is minimized through various specification and digital control system and this product provides high performance, low ion balance. Also, wide range of ionization is possible through optimum ion generating design.
Key Features
- Depending on the polarity, ion generation amount is automatically controlled. – Auto. Duty
- With its slim body, diverse installation is possible
- Maximized the ion creation via reducing loss of corona discharging
- Tip Cleaning Alarm (internal timer installed → possible to set tip cleaning period)
- Output voltage control (8~12.5kVp-p)
- Power jumping function among ion bars (Max. 4 ion bar links)
- Aerodynamic design nozzle socket reduces tip contamination
- One-touch in/out socket application
- Tip cleaning device (Option)
- Design for minimum air consumption (Newly designed socket minimized the air consumption but maximized the air pressure)
Do you need any other help?
Parameter | Description / Value | Remark | |
---|---|---|---|
Input Power | DC 24V (±5%) | ||
Power Consumption | Max. 14.4W | ||
Current Consumption | Max. 500mA | DC 24V | |
Ion-Generation Method | Corona Discharge Pulse AC | ||
Air Purge Supply Pressure | 0.1MPa ~ 0.5 MPa | CDA (Clean Dry Air), N2 | |
Air Purge Connection Port | Pipe Thread 1/8” | ||
Ion Balance | within ±30V | 1,000mm | |
Ozone (O3) Concentration | ≤0.05ppm | ||
Main Body Material | Non-Flammable ABS | Level V0 | |
Electrode Material | Standard : Tungsten | ||
Option : Silicon, Titanium | |||
Electrode Replacement | Cartridge type | ||
Operation Circumstance | 0°C ~ +50°C (32°F ~ 122°F), 35% ~ 85% RH | ||
Ion Bar Length | 877mm ~ 3,478mm | ||
Mounting Method | Bolt Mounting with Bracket | ||
Function | Remote Control | ||
Adjust Function | Frequency [Hz] | 0.1, 0.3, 1, 3, 5, 8, 10, 20, 30, 35, 40, 45, 50 | |
Voltage [Level] | Positive 1 ~ 10 / Negative 1 ~ 10 | ||
Duty Ratio [%] | 40 ~ 70 | ||
Auto Duty | Mode Set | Distance 50 ~ 100mm | |
Alarm Function | High Voltage Abnormal Alarm, Tip Cleaning Alarm (Setting) | ||
Interface | Run State, Remote, RS485, Alarm(High Voltage Abnormal, Tip Cleaning) | ||
Operating Distance | 50mm ~ 2,000mm | ||
Option | RMS (Real Monitoring System), SBP-RD (DC Power Supply) | ||
Warranty | 1 year |
※ Product model number will be differ as the discharge needle specifications. ex.) Tungsten : SIB4-**** / Silicon : SIB4-****-SI / Titanium : SIB4-****-TI
※ The appearance and specification of the product may be changed without prior notice for the improvement of the product.
Test Conditions
- Model : SIB4-1000
- Socket : SIE-4
- Output Voltage : Pulse AC ±10.5kVp-p
- Air Pressure : 0.3MPa
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃ ± 1℃, 40% ± 2%RH
- Charge Plate Capacitance : 20pF ± 2pF (150 X 150mm)
- Frequency : 30Hz
MODEL / DIMENSIONS
No. | Model No. | Tip Q’TY | A | B | C | D | E | Middle BKT Q’TY |
---|---|---|---|---|---|---|---|---|
1 | SIB4-800 | 12 | 660 | 800 | 851 | 877 | 70 | - |
2 | SIB4-900 | 14 | 780 | 881 | 932 | 958 | 50.5 | - |
3 | SIB4-1000 | 16 | 900 | 1001 | 1052 | 1078 | 50.5 | 1 |
4 | SIB4-1100 | 18 | 1020 | 1121 | 1172 | 1198 | 50.5 | 1 |
5 | SIB4-1200 | 20 | 1140 | 1241 | 1292 | 1318 | 50.5 | 1 |
6 | SIB4-1300 | 22 | 1260 | 1361 | 1412 | 1438 | 50.5 | 1 |
7 | SIB4-1500 | 24 | 1380 | 1481 | 1532 | 1558 | 50.5 | 1 |
8 | SIB4-1600 | 26 | 1500 | 1601 | 1652 | 1678 | 50.5 | 1 |
9 | SIB4-1700 | 28 | 1620 | 1721 | 1772 | 1798 | 50.5 | 2 |
10 | SIB4-1800 | 30 | 1740 | 1841 | 1892 | 1918 | 50.5 | 2 |
11 | SIB4-2000 | 32 | 1860 | 1961 | 2012 | 2038 | 50.5 | 2 |
12 | SIB4-2100 | 34 | 1980 | 2081 | 2132 | 2158 | 50.5 | 2 |
13 | SIB4-2200 | 36 | 2100 | 2201 | 2252 | 2278 | 50.5 | 2 |
14 | SIB4-2300 | 38 | 2220 | 2321 | 2372 | 2398 | 50.5 | 2 |
15 | SIB4-2500 | 40 | 2340 | 2441 | 2492 | 2518 | 50.5 | 3 |
16 | SIB4-2700 | 44 | 2580 | 2681 | 2732 | 2758 | 50.5 | 3 |
17 | SIB4-3000 | 48 | 2820 | 2921 | 2972 | 2998 | 50.5 | 3 |
18 | SIB4-3200 | 52 | 3060 | 3161 | 3212 | 3238 | 50.5 | 3 |
19 | SIB4-3400 | 56 | 3300 | 3401 | 3452 | 3478 | 50.5 | 3 |
Download Catalogue, Manual & Leaflet
Technical Support
Telephone Consultation
- Features
-
SIB4 Series
Corona discharge loss is minimized through various specification and digital control system and this product provides high performance, low ion balance. Also, wide range of ionization is possible through optimum ion generating design.
Key Features
- Depending on the polarity, ion generation amount is automatically controlled. – Auto. Duty
- With its slim body, diverse installation is possible
- Maximized the ion creation via reducing loss of corona discharging
- Tip Cleaning Alarm (internal timer installed → possible to set tip cleaning period)
- Output voltage control (8~12.5kVp-p)
- Power jumping function among ion bars (Max. 4 ion bar links)
- Aerodynamic design nozzle socket reduces tip contamination
- One-touch in/out socket application
- Tip cleaning device (Option)
- Design for minimum air consumption (Newly designed socket minimized the air consumption but maximized the air pressure)
Do you need any other help?
Do you need product inquiries or technical support? If you have any questions or concerns, please contact us here. - Specification
-
Parameter Description / Value Remark Input Power DC 24V (±5%) Power Consumption Max. 14.4W Current Consumption Max. 500mA DC 24V Ion-Generation Method Corona Discharge Pulse AC Air Purge Supply Pressure 0.1MPa ~ 0.5 MPa CDA (Clean Dry Air), N2 Air Purge Connection Port Pipe Thread 1/8” Ion Balance within ±30V 1,000mm Ozone (O3) Concentration ≤0.05ppm Main Body Material Non-Flammable ABS Level V0 Electrode Material Standard : Tungsten Option : Silicon, Titanium Electrode Replacement Cartridge type Operation Circumstance 0°C ~ +50°C (32°F ~ 122°F), 35% ~ 85% RH Ion Bar Length 877mm ~ 3,478mm Mounting Method Bolt Mounting with Bracket Function Remote Control Adjust Function Frequency [Hz] 0.1, 0.3, 1, 3, 5, 8, 10, 20, 30, 35, 40, 45, 50 Voltage [Level] Positive 1 ~ 10 / Negative 1 ~ 10 Duty Ratio [%] 40 ~ 70 Auto Duty Mode Set Distance 50 ~ 100mm Alarm Function High Voltage Abnormal Alarm, Tip Cleaning Alarm (Setting) Interface Run State, Remote, RS485, Alarm(High Voltage Abnormal, Tip Cleaning) Operating Distance 50mm ~ 2,000mm Option RMS (Real Monitoring System), SBP-RD (DC Power Supply) Warranty 1 year ※ Product model number will be differ as the discharge needle specifications. ex.) Tungsten : SIB4-**** / Silicon : SIB4-****-SI / Titanium : SIB4-****-TI
※ The appearance and specification of the product may be changed without prior notice for the improvement of the product.
- Decay Time Characteristics
-
Test Conditions
- Model : SIB4-1000
- Socket : SIE-4
- Output Voltage : Pulse AC ±10.5kVp-p
- Air Pressure : 0.3MPa
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃ ± 1℃, 40% ± 2%RH
- Charge Plate Capacitance : 20pF ± 2pF (150 X 150mm)
- Frequency : 30Hz
- Dimensions
-
MODEL / DIMENSIONS
No. Model No. Tip Q’TY A B C D E Middle BKT Q’TY 1 SIB4-800 12 660 800 851 877 70 - 2 SIB4-900 14 780 881 932 958 50.5 - 3 SIB4-1000 16 900 1001 1052 1078 50.5 1 4 SIB4-1100 18 1020 1121 1172 1198 50.5 1 5 SIB4-1200 20 1140 1241 1292 1318 50.5 1 6 SIB4-1300 22 1260 1361 1412 1438 50.5 1 7 SIB4-1500 24 1380 1481 1532 1558 50.5 1 8 SIB4-1600 26 1500 1601 1652 1678 50.5 1 9 SIB4-1700 28 1620 1721 1772 1798 50.5 2 10 SIB4-1800 30 1740 1841 1892 1918 50.5 2 11 SIB4-2000 32 1860 1961 2012 2038 50.5 2 12 SIB4-2100 34 1980 2081 2132 2158 50.5 2 13 SIB4-2200 36 2100 2201 2252 2278 50.5 2 14 SIB4-2300 38 2220 2321 2372 2398 50.5 2 15 SIB4-2500 40 2340 2441 2492 2518 50.5 3 16 SIB4-2700 44 2580 2681 2732 2758 50.5 3 17 SIB4-3000 48 2820 2921 2972 2998 50.5 3 18 SIB4-3200 52 3060 3161 3212 3238 50.5 3 19 SIB4-3400 56 3300 3401 3452 3478 50.5 3 - Download
-