SXN-05U
![](https://sunstat.com/wp-content/uploads/2024/11/SXN-05U@2x-100.jpg)
Key Features
- Optimized models for electrostatic removal of ultra-sensitive devices such as LCD glass, wafers, and PCBs
- All-in-one controller that can be used without purchasing a separate controller
- Due to its small size, it can be installed and used without restriction even in a small space.
- Ion Balance ± 0V
- Maintain initial performance throughout its lifetime
- No CDA required, no particle scattering
- According to Article 8 of the Enforcement Decree of the Nuclear Safety Act, it may be excluded from regulation according to tube voltage.
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
Parameter | Description / Value | Remarks |
---|---|---|
Ion Generation Method | Soft X-ray | – |
Source | Soft X-ray Tube | – |
Tube Voltage | 4.9kV | – |
Tube Current | 400uA | – |
Cooling Method | Natural Air Cooling | – |
Mounting Method | Bolt Mounting with Bracket | – |
Power Cunsumption | 8W | – |
Current Cunsumption | Max. 36mA | AC 220V |
Operation Circumstance | 0℃ ~ +50℃(32℉ ~ 122℉), 35% ~ 85% RH | – |
Weight | 0.4Kg | – |
Input Power | AC 100~240V, 50/60Hz(Adaptor Input) | DC 12V, 1A Adapter |
Alarm | Head Fail | – |
Warning | Life Time Over | – |
Remote / Interlock | Remote / Interlock On, Off Control | – |
Indicator | Alarm State, Over Time State | – |
Warranty | 1 Year | – |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
![](https://sunstat.com/wp-content/uploads/2024/11/05kv@1.jpg)
Dimensions
![](https://sunstat.com/wp-content/uploads/2024/11/SXN-05U_D-100.jpg)
Shielding method
- Please refer to the following graph and table to select the material and thickness of the shield.
- Warring
- For the safety of the user, please be sure to shield the irradiation space where the X-ray is generated.
- After shielding, connect the interlock contacts to the door so that when the door is opened, the X-ray generation stops.
![](https://sunstat.com/wp-content/uploads/2024/11/Asset-3@1.5x-100.jpg)
Shielding installation diagram
- If soft X-rays are directly irradiated to the human body, they may affect the skin, so be sure to use shielding as shown in the figure.
- Before running the Soft X-Ray Ionizer, check the shielding status of the equipment and use the interlock function.
- The radiation dose should be kept below 1μSv/hr for 5kV products and 10μSv/hr for 10kV & 15kV products. (Leakage standards may vary by country)