Home / Business Area / Electrostatic Solution / Soft X-ray Ionizer / SXB-05NSRL Series
SXB-05NSRL Series
Key Features
- Superior power performance compared to SXB-05NR by applying high current
- Efficient design application is possible even in various spaces and restrictive (obstacle) spaces
- Ion Balance ± 0V
- Maintain initial performance over its lifetime
- No Clean Dry Air (CDA) required, no particle scattering
- Apply up to 9 tubes for a wide range of festivals
- Tube module structure for quick on-site replacement with easy separation and mating
- Economical maintenance by purchasing the tube separately
- According to Article 8 of the Enforcement Decree of the Nuclear Safety Act, it may be exempt from regulation depending on tube voltage.
Download
You will receive catalogues, manuals and leaflets.
Technical Support & Customer Support
Specifications
Parameter | Description / Value |
---|---|
Ion Generation Method | Soft X-ray |
Source | Soft X-ray Tube |
Tube Voltage | 4.9kV |
Beam Angle | 150˚ |
Power Consumption | Max. 150W |
Operation Circumstance | 0℃ ~ +50℃(32℉ ~ 122℉), 35% ~ 85% RH |
Warranty | 1 year |
Decay Time Characteristics
- Decay Time : ±1,000V to ±100V
- Temperature & Humidity : 24℃, 50%RH
- Charge Plate Capacitance : 20pF (150 X 150mm)
Dimensions
Dimensions Table
No. | Model No. | Tube Q’ty | A | B | C | D | Mid. BRKT Q’ty |
---|---|---|---|---|---|---|---|
1 | SXB-05NSRL-300-1 | 1 | 357 | 381 | 410 | – | – |
2 | SXB-05NSRL-600-2 | 2 | 668 | 692 | 721 | 311 | 2 |
3 | SXB-05NSRL-900-3 | 3 | 979 | 1003 | 1032 | ||
4 | SXB-05NSRL-1200-4 | 4 | 1290 | 1314 | 1343 | ||
5 | SXB-05NSRL-1500-5 | 5 | 1601 | 1625 | 1654 | ||
6 | SXB-05NSRL-1800-6 | 6 | 1912 | 1936 | 1965 | ||
7 | SXB-05NSRL-2200-7 | 7 | 2223 | 2247 | 2276 | 3 | |
8 | SXB-05NSRL-2500-8 | 8 | 2534 | 2558 | 2587 | ||
9 | SXB-05NSRL-700-2 | 2 | 777 | 801 | 830 | 420 | 2 |
10 | SXB-05NSRL-1100-3 | 3 | 1117 | 1221 | 1250 | ||
11 | SXB-05NSRL-1500-4 | 4 | 1617 | 1641 | 1670 | ||
12 | SXB-05NSRL-2000-5 | 5 | 2037 | 2061 | 2090 | ||
13 | SXB-05NSRL-2400-6 | 6 | 2457 | 2481 | 2510 | 3 | |
14 | SXB-05NSRL-2800-7 | 7 | 2877 | 2901 | 2930 | ||
15 | SXB-05NSRL-3200-8 | 8 | 3297 | 3321 | 3350 |
Shielding method
- Please refer to the following graph and table to select the material and thickness of the shield.
- Warring
- For the safety of the user, please be sure to shield the irradiation space where the X-ray is generated.
- After shielding, connect the interlock contacts to the door so that when the door is opened, the X-ray generation stops.
Shielding installation diagram
- If soft X-rays are directly irradiated to the human body, they may affect the skin, so be sure to use shielding as shown in the figure.
- Before running the Soft X-Ray Ionizer, check the shielding status of the equipment and use the interlock function.
- The radiation dose should be kept below 1μSv/hr for 5kV products and 10μSv/hr for 10kV & 15kV products. (Leakage standards may vary by country)
Option
Key Features
- Repeater to extend the length of the cable connecting the Photo Bar and the Controller
- Cable lengths can be extended up to 10 m
Download
You will receive catalogues, manuals and leaflets.
Specifications
Parameter | Description / Value |
---|---|
Weight | 0.26kg |
Warranty | 1 year |